1.
Journal of Biomedical Engineering ; (6): 401-408, 2023.
Article in Chinese | WPRIM | ID: wpr-981556

ABSTRACT

In transcranial magnetic stimulation (TMS), the conductivity of brain tissue is obtained by using diffusion tensor imaging (DTI) data processing. However, the specific impact of different processing methods on the induced electric field in the tissue has not been thoroughly studied. In this paper, we first used magnetic resonance image (MRI) data to create a three-dimensional head model, and then estimated the conductivity of gray matter (GM) and white matter (WM) using four conductivity models, namely scalar (SC), direct mapping (DM), volume normalization (VN) and average conductivity (MC), respectively. Isotropic empirical conductivity values were used for the conductivity of other tissues such as the scalp, skull, and cerebrospinal fluid (CSF), and then the TMS simulations were performed when the coil was parallel and perpendicular to the gyrus of the target. When the coil was perpendicular to the gyrus where the target was located, it was easy to get the maximum electric field in the head model. The maximum electric field in the DM model was 45.66% higher than that in the SC model. The results showed that the conductivity component along the electric field direction of which conductivity model was smaller in TMS, the induced electric field in the corresponding domain corresponding to the conductivity model was larger. This study has guiding significance for TMS precise stimulation.


Subject(s)
Transcranial Magnetic Stimulation , Diffusion Tensor Imaging , Electric Conductivity , Electricity , Scalp
2.
Journal of Biomedical Engineering ; (6): 1-7, 2023.
Article in Chinese | WPRIM | ID: wpr-970667

ABSTRACT

Existing neuroregulatory techniques can achieve precise stimulation of the whole brain or cortex, but high-focus deep brain stimulation has been a technical bottleneck in this field. In this paper, based on the theory of negative permeability emerged in recent years, a simulation model of magnetic replicator is established to study the distribution of the induced electric field in the deep brain and explore the possibility of deep focusing, which is compared with the traditional magnetic stimulation method. Simulation results show that a single magnetic replicator realized remote magnetic source. Under the condition of the same position and compared with the traditional method of stimulating, the former generated smaller induced electric field which sharply reduced with distance. By superposition of the magnetic field replicator, the induced electric field intensity could be increased and the focus could be improved, reducing the number of peripheral wires while guaranteeing good focus. The magnetic replicator model established in this paper provides a new idea for precise deep brain stimulation, which can be combined with neuroregulatory techniques in the future to lay a foundation for clinical application.


Subject(s)
Brain , Cerebral Cortex , Computer Simulation , Electricity , Magnetic Fields
3.
Journal of Biomedical Engineering ; (6): 10-18, 2022.
Article in Chinese | WPRIM | ID: wpr-928194

ABSTRACT

Electric field stimulation (EFS) can effectively inhibit local Ca 2+ influx and secondary injury after spinal cord injury (SCI). However, after the EFS, the Ca 2+ in the injured spinal cord restarts and subsequent biochemical reactions are stimulated, which affect the long-term effect of EFS. Polyethylene glycol (PEG) is a hydrophilic polymer material that can promote cell membrane fusion and repair damaged cell membranes. This article aims to study the combined effects of EFS and PEG on the treatment of SCI. Sprague-Dawley (SD) rats were subjected to SCI and then divided into control group (no treatment, n = 10), EFS group (EFS for 30 min, n = 10), PEG group (covered with 50% PEG gelatin sponge for 5 min, n = 10) and combination group (combined treatment of EFS and PEG, n = 10). The measurement of motor evoked potential (MEP), the motor behavior score and spinal cord section fast blue staining were performed at different times after SCI. Eight weeks after the operation, the results showed that the latency difference of MEP, the amplitude difference of MEP and the ratio of cavity area of spinal cords in the combination group were significantly lower than those of the control group, EFS group and PEG group. The motor function score and the ratio of residual nerve tissue area in the spinal cords of the combination group were significantly higher than those in the control group, EFS group and PEG group. The results suggest that the combined treatment can reduce the pathological damage and promote the recovery of motor function in rats after SCI, and the therapeutic effects are significantly better than those of EFS and PEG alone.


Subject(s)
Animals , Rats , Electric Stimulation , Polyethylene Glycols/therapeutic use , Rats, Sprague-Dawley , Recovery of Function/physiology , Spinal Cord , Spinal Cord Injuries/therapy
4.
Journal of Biomedical Engineering ; (6): 232-240, 2021.
Article in Chinese | WPRIM | ID: wpr-879270

ABSTRACT

Spinal cord stimulation (SCS) for pain is usually implanted as an open loop system using unchanged parameters. To avoid the under and over stimulation caused by lead migration, evoked compound action potentials (ECAP) is used as feedback signal to change the stimulating parameters. This study established a simulation model of ECAP recording to investigate the relationship between ECAP component and dorsal column (DC) fiber recruitment. Finite element model of SCS and multi-compartment model of sensory fiber were coupled to calculate the single fiber action potential (SFAP) caused by single fiber in different spinal cord regions. The synthetized ECAP, superimposition of SFAP, could be considered as an index of DC fiber excitation degree, because the position of crests and amplitude of ECAP corresponds to different fiber diameters. When 10% or less DC fibers were excited, the crests corresponded to fibers with large diameters. When 20% or more DC fibers were excited, ECAP showed a slow conduction crest, which corresponded to fibers with small diameters. The amplitude of this slow conduction crest increased as the stimulating intensity increased while the amplitude of the fast conduction crest almost remained unchanged. Therefore, the simulated ECAP signal in this paper could be used to evaluate the degree of excitation of DC fibers. This SCS-ECAP model may provide theoretical basis for future clinical application of close loop SCS base on ECAP.


Subject(s)
Action Potentials , Computer Simulation , Electric Stimulation , Evoked Potentials , Spinal Cord , Spinal Cord Stimulation
5.
Journal of Biomedical Engineering ; (6): 151-155, 2018.
Article in Chinese | WPRIM | ID: wpr-771105

ABSTRACT

Bioartificial liver support system (BALSS) provides a new way to treat liver failure and leaves more time for patients who are waiting for liver transplantation. It has detoxification function as well as the human liver, at the same time it can provide nutrition and improve the internal environment inside human body. Bioreactors and hepatocytes with good biological activity are the cores of BALSS which determine the treatment effect. However, in the course of prolonged treatment, the function and activity of hepatocytes might be greatly changed which could influence the efficacy. Therefore, it is very important to detect the status of the hepatocytes in BALSS. This paper presents some common indicators of cell activity, detoxification and synthetic functions, and also introduces the commonly detection methods corresponding to each indicator. Finally, we summarize the application of detection methods of the hepatocyte status in BALSS and discuss its development trend.

6.
Journal of Biomedical Engineering ; (6): 564-570, 2018.
Article in Chinese | WPRIM | ID: wpr-687594

ABSTRACT

Modified electroconvulsive therapy (MECT) and magnetic seizure therapy (MST) are effective treatments for severe major depression. MECT has better efficacy in the treatment than MST, but it has cognitive and memorial side effects while MST does not. To study the causes of these different outcomes, this study contrasted the electric filed strength and spatial distribution induced by MECT and MST in a realistic human head model. Electric field strength induced by MECT and MST are simulated by the finite element method, which was based on a realistic human head model obtained by magnetic resonance imaging. The electrode configuration of MECT is standard bifrontal stimulation configuration, and the coil configuration of MST is circular. Maps of the ratio of the electric field strength to neural activation threshold are obtained to evaluate the stimulation strength and stimulation focality in brain regions. The stimulation strength induced by MECT is stronger than MST, and the activated region is wider. MECT stimulation strength in gray matter is 17.817 times of that by MST, and MECT stimulation strength in white matter is 23.312 times of that by MST. As well, MECT stimulation strength in hippocampi is 35.162 times of that by MST. More than 99.999% of the brain volume is stimulated at suprathreshold by MECT. However, MST activated only 0.700% of the brain volume. The stimulation strength induced by MECT is stronger than MST, and the activated region is wider may be the reason that MECT has better effectiveness. Nevertheless, the stronger stimulation strength in hippocampi induced by MECT may be the reason that MECT is more likely to give rise to side effects. Based on the results of this study, it is expected that a more accurate clinical quantitative treatment scheme should be studied in the future.